IP Camera F/W Release History [2022.4.12 relese note] * version : 1.4.11 * updates : - apache update 2.4.51 -> 2.4.53 [2021.11.22 relese note] * version : 1.4.10 * updates : - apache update 2.4.43 -> 2.4.51 [2020.11.06 relese note] * version : 1.4.9 * updates : - fixed videocoder freeze issue with brightness 0~2 [1.4.8 release note] * TARGET : ALL 1. fixed socket accumulation with network information [1.4.7 release note] * TARGET : ALL 1. apache update 2.4.43 -> 2.4.46 2. added onvif motion event compatability (hikvision) [1.4.6 release note] * TARGET : ALL 1. increased apache timeout 300 -> 900 2. improved onvif motion event reliability [1.4.5 release note] * TARGET : ALL 1. apache update -> 2.4.43 2. openssl update -> 1.1.1g 3. upnp update -> 1.12.1 4. general but fixes with rtsp and apache [1.4.4 release note] * INTERNAL RELEASE [1.4.3 release note] * TARGET : ALL 1. Update Apache web server [1.4.2 release note] * TARGET : ALL 1. Applied new internal storage method. 2. Setting saving sync with onvif 3. FIXED onvif time_set. [1.4.1 release note] * TARGET : ALL 1. FIXED sdk motion api. [1.4.0 release note] * TARGET : ALL 1. apache update.(web server) [1.3.3 release note] 1. Changed Encode settings CBR => CBR1 (idx 5) rcqpmin = 8; rcqpmax = 44 2. Add a Save button on the CAMEAR SETUP Web page. [1.3.2 release note] * TARGET : 2700, 1900 IP-PVM 1. Remove code of ISP initial and Zoom control on Boot. [1.3.1 release note] * Target Model : All 1. Updated to latest Live555 Library (2017.04.26) [1.3.0 release note] * Target Model : All 1. Added ONVIF On/Off Port settings 2. Changed JPEG default to JPEG 800x600, 5fps, 50베 3. Changed Motion API (can be set to either 12, 48 Grid) [1.2.3 release note] * Target Model : WDP-80D2MV 1. Added Avigilon VMS support [1.2.3 release note] * Target model : WDP-18TW2M 1. Improved ONVIF Authentication 2. added H264 Quality setting savings [1.2.3 release note] * Target Model : WDP84ML2M 1. Fixed ONVIF Motion Event bug [1.2.2 release note] * Target Model : WDP84ML2M 1. Added ONVIF Motion Event [1.2.1 release note] * Target Model : WDP17S05MF, WDP4602MXV, WDP4608MXV 1. NTP Client Timeout changed to 8 seconds [1.2.0 release note] 1. Bug Fix: ONVIF Video Encoder Information Switch Error 2. Added SDK API (NTP/Manual mode) [1.1.8 release note] * Target Model : 17S05MF 1. Onvif Video Encoder Configuration Switching Problem.(h264 <=> mjpeg) [1.1.7 release note] * Target Model : 4608, 4602, 17S05MF 1. Added 12 Grid Verint [1.1.6 release note] 1. Improved motion detection stability 2. httpd-2.2.31 update 3. openssl-0.9.8zh update 4. Removed MJPEG server push (changed to JPEG download) 5. Fixed G711 audio streaming issue [1.1.3 release note] Changed Model # WDP79BS1M to WDP79BS2M [1.1.2 release note] Target model = WDP-79BS2M 1. Added H264_Profile change interface (Baseline, Main, High) -It requires 20 seconds for change to take effect. 2. Added RTSP SDP information 3. Changed default values for WDP-79BSS1M - Lenstype=manual - Daynight=audio 4. Bug fix - Abnormal shutter speed - Abnormal when lens type is manual - Slow brightness response [1.1.1 release note] 1. Added WDP-18TW2M 2. Applied ISP_RESET to OV10635 [1.1.0 release note] 1. Zoom, focus debugging Stop command right after control control command. 2. Removed 4399, 5499 nickname. 3. Upgrade bugfix - Increased 23MB to 37MB 4. Changed motion sensitivity. - Lowered 1080p sensitivity. Increased for others. 5. Added WDP-82FD2M [1.0.1 bug fix - 20150625] 1. Fixed mp4 container medatada error during SD card recording. [1.0.1 release note - 20150401] 1. Same as 1.0.0. Upgrade test version. [1.0.0 release note - 20150401] 1. ONVIF 2.2 2. Increased filesystem size due to ONVIF library Two step firmware update is required when first updating to ONVIF firmware. 3. After the firmware update, the firmware file name extension will change to .bin 4. Added UpdateMamanger Supports different upgrade functions (useful when the camera is unresponsive, inoperable) 5. Increased motion block to 8x6 Changed Motion Configuration API [0.5.23 release note - 20141028] 1. Blocks network after a firmware file has been uploaded for update. [0.5.22 release note - 20141028] 1. Modified param.cgi to fastcgi => Separated jpeg (jpeg_download, mjpg_download) => Added get_image.cgi (added jpeg functionality) => Connection instance gets generated only once at the beginning when using PostgreSQL [0.5.21 release note - 20140926] 1. Same as 0.5.20. test firmware [0.5.20 release note - 20140926] 1. DEBUG print OFF 2. Dblogs file is not generated 3. Changed Restart to Reboot 4. Firmware upgrade bar during upgrade (web access) 5. Network is blocked after an upgrade firmware file is uploaded 6. Codec is maintained during firmware upgrade [0.5.19 release note - 20140919] 1. Same as 0.5.18 [0.5.18 release note - 20140919] 1. Test firmware with debug information [0.5.17 release note - 2014/09/01] 1. Same as 0.5.16. This is upgrade test version [0.5.16 release note - 2014/09/01] 1. Fixed system freeze during upgrade issue 2. Added S/W watchdog (system restart when network, web-server fails to start) [0.5.15 release note - 20140822] 1. Fixed a bug that was introduced with version 0.5.14 where the factory set, hard_factory (from the API) would not work properly [0.5.14 release note - 20140820] 1. Applied Verint requested default values [0.5.13 release note - 20140711] 1. CAM-55. Live View using port 80. This applies to MJPEG only. From the Live View, the H.264 or MJPEG can be selected. Live View port 80 works with MJPEG only. 2. Fixed freezing issues [0.5.12 release note - 20140711] 1. Fixed a bug with the Log Delete [0.5.11 release note - 20140701] 1. Added High, Medium, Low video quality to the VBR based on the table below. For the ATM camera, the table applies up to 1280x1024. Resolution HIGH MEDIUM LOW 1920x1080 10000 7000 4000 1280x1024 10000 7000 4000 1280x720 8000 6000 4000 1024x768 8000 6000 4000 800x600 4000 3000 2000 800x480 4000 3000 2000 640x480 4000 3000 2000 2. Added Image Quality to the API 3. Added FTP passive/active mode 4. gop size changed from U32 to U16 [0.5.10 release note - 20140620] 1. CAM-55 2. Fixed ATM camera freezing issue [0.5.9 release note - 20140612] 1. Bug Fix. ATM camera video, Web GUI Freeze issue [0.5.7 release note - 20140605] 1. Video Loss less than 1 second => fps, bitrate, gop, mjpeg-qp, mjpeg-fps 2. Expanded ftp port to 65535 3. Fixed JPEG QP (was not being configured previously) [0.5.7 release note - 20140605] 1. Fixed bug where the “ename” message was missing 2. Fixed bug where the API would not return the setting values that were updated through the web page 3. Added code to prevent impossible resolution combinations If the MJPEG is disabled, the motion grid in the web page will not be displayed 4. Added SET button to the AWC. (calibrate White Balance by placing a pure white sheet of paper in front of the camera, and press AWC for a permanent white balance – until the next calibration) [0.5.6 release note - 20140603] 1. Fixed Motion Event Not Sending Issue [0.5.4 – 0.5.5 release note - 20140530] 1. Fixed CAM-77 2. Fixed issue where the camera would freeze when the Recorder Sever is restarted [0.5.3 release note - 20140523] 1. Improved VBR API: If venc.brc is VBR, venc.kbps will not get configured. [0.5.2 release note - 20140515] 1. Implemented a better VBR. a. SDK: If venc.brc is VBR, venc.kbps cannot be configured. [0.5.2 release note - 20140515] 1. Fixed a bug that started with 0.5.1. – When the camera was rebooted with motion enabled, the motion would not be triggered [0.5.1 release note - 20140514] 1. CAM-63 Fixed. (There was a bug where the event information was not being sent when recipients were added/deleted/added again. 2. GOP range is 1-30 3. Changed bps to kbps in the API. 4. Changed the minimum bitrate value from 64k to 400k (same as web UI) 5. CAM-76. Video quality improvement is finalized, pending Verint evaluation 6. CAM-77. Camera freeze has been finalized. [0.5.0 release note - 20140509] - CAM-67, CAM-76, and CAM-77 are all related. We will continue to improve on these items. 1. CAM-75 Failed Factory default call Fixed. In version 0.4.15, the return values were not correct. However, it was working correctly internally. With version 0.5.0, the return values have been corrected. 2. CAM-67 Big I-frame size Changed initial encoder settings, and confirmed iframe size similar to Costar. (1080p, 15fps, VBR, 4000000 bps, stream2 disabled) 4. CAM-76 partial. Video quality is not acceptable. With the implementation of CAM-77, the quality has been improved. We will fine-tune more. 5. CAM-77 partial. Camera-freeze when changing resolutions We have identified the root cause. For now, the freezing has been patched, however the camera might not be sending images. This will be fixed with the next firmware version. 6. Others: • The minimum birate value has been modified to 400kbps (video profile – web gui). The bitrate range has been amplified. Maximum value has not changed. The SDK has been updated. [0.4.15 release note - 20140430] 1. CAM-75 : Factory default without loosing Network parameter. 2. CAM-63.new issue : Event TCP Connection We are not able to duplicate this. 3. CAM-69 : Cannot manually set a custom camera password in Weldex Web GUI. 4. CAM-51 : The Camera takes ~15 sec to apply a resolution change. [0.4.14 release note - 20140418] 1. CAM-70 - 1024x768 resolution system freeze => Fixed. Might be root cause for CAM-73, CAM-74 2. CAM-64 - HTTP 500 Internal Server Error => Fixed. Web server tune-up 3. CAM-63 - Need camera to establish the Event TCP connection as soon as a Recipient is added => Fixed. 4. CAM-39 => Applied VLC loading delay to live view. There is a 5 second delay for 30fps, The delay will be increased as the fps is decreased. There will be a maximum of 11 seconds delay for 1fps. 5. Added Telnetd on/off API. => Refer to WELDEX_HTTP_API_Translated_20140418.doc 8.4. telnet login account (root/solidblue) [0.4.13 release note - 20140328] 1. CAM-36 Support configuration video settings individually [0.4.12 release note - 20140324] 1. Height Strip Camera => Bug Fix, Not Play Audio Alarm Out (issue found internally) [0.4.11 release note - 20140321] 1. Fixed an issue where the stream was broken after changing to PAL mode. [0.4.10 release note - 20140320] 1. Test firmware (to test upgrade function) [0.4.9 release note - 20140320] 1. Fixed CAM-65 Internal Server Error after firmware upgrade. 2. Fixed CAM-66 No cgi API command to get the Firmware Version => Added device_info.fwversion. 3. Fixed CAM-58 Video Output NTSC/PAL not supported WDP-17S05MF model 4. Fixed CAM-33 PAL video mode issue 5. Fixed CAM-62 IPScanTool related issues * Issue 1 - Could not PING to the camera ( Has no DHCP Server) => OK * Issue 2 - Why would this not work with an unmanaged switch between the PC and camera? => OK * Issue 3 - The Camera disappeared from the list. => OK * Another Issue - Tested Virtual Box Bridge, NAT. => OK [0.4.8 release note - 20140314] 1. CAM-65 Internal Server Error after firmware upgrade => Increased web-server time out duration 2. CAM-30 Unsecured telnet connection => Telnetd service has been disabled [0.4.7 release note - 20140311] 1. Version up and added reservation area on system configuration file for CAM29 test (Approximately 40bytes) [0.4.6 release note - 20140310] 1. Fixed CAM-54 The camera freezes after sending a command to change the frame rate 2. Fixed CAM-29 Camera does not retain settings after a firmware upgrade 3. Fixed CAM-60 Default password is 9999 4. Fixed Maintenance=>Import Configuration. [0.4.5 release note - 20140221] 1. Supported Keep the TCP Connection opened for Recipients. 2. Validate the credentials for all the cgi (ONVIF temporarily disabled) 3. Push NO_MOTION EVENT [0.4.4 release note - 20140217] 1. Same as 0.4.3. Test firmware to verify upgrade SDK. [0.4.3 release note - 20140214] 1. SDK => Forced I Frame CGI added => Firmware update CGI added => Camera Setup CGI added [0.4.2 release note - 20140207] 1. Added APIPA - zeroconfig a) It checks during boot-up. 2. RTP packet size changed to MTU (1500 bytes 3. Changed Height Strip Model Name to WDP-4602MXV 4. Improved Motion accuracy 5. SDK a) Fixed bug: action=update_motion return value is -1 b) Added GOP and QP to the stream table. c) Added routine to check value for each field for highest and lowest allowed value d) Changed bitrate_control field name to: => rate_control e) Added information on how to get Event Information from the IP camera f) Added description on -1 normally error. This is a general error message => Changed name to “general error” 4) Fixed bitrate setting bug => Actual bitrate should be entered. Range 2000000 ~ 10000000